Model Number : TN11LDC

Place of Origin : China

Brand Name : Huawei

TN11LDC : 2 x 100Gbit/s Into OTUC2 Wavelength Conversion Board

Packaging Details : Export carton package

Port : Shenzhen

Supply Ability : 200 Piece/Pieces per Week

Price : Negotiable

Certification : CE FCC RoHS

MOQ : Negotiable

Delivery Time : 7-15 days

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Contact Now

Contact Us

OptiX OSN 9800 TN11LDC 2 x 100Gbit/s Service Multiplexing Into OTUC2 Wavelength Conversion Board-- OSN9800 UPS

Functions and Features

The LDC board is mainly used to achieve wavelength tunable and to provide OTN interfaces and ESC.

For detailed functions and features, see Table 1.

Table 1 Functions and features of the LDC board
Function and FeatureDescription
Basic function

The LDC board on the client side receives four types of signals, which are OTU4, 100GE, FC3200, and FC1600. The LDC converts signals as follows:

200G line:

  • 2 x OTU4 <-> 2 x ODU4 <-> 1 x ODUC2 <-> 1 x OTUC2
  • 2 x 100GE <-> 2 x ODU4 (Bit transparent mapping/MAC transparent mapping) <-> 1 x OTUC2
  • 2 x 100GE <-> 2 x ODUflex (MAC transparent mapping) <-> 2 x ODU4 <-> ODUC2 <-> 1 x OTUC2
  • 2 x FC3200 <-> 2 x ODUflex <-> 1 x ODUC2 <-> 1 x OTUC2
  • 2 x FC1600 <-> 2 x ODUflex <-> 1 x ODUC2 <-> 1 x OTUC2

100G line:

  • 1 x OTU4 <-> 1x ODU4 <-> 1 x OTU4
  • 1 x 100GE <->1 x ODU4 (Bit transparent mapping/MAC transparent mapping) <-> 1 x OTU4
  • 1 x 100GE <-> 1 x ODUflex (MAC transparent mapping) <-> 1 x ODU4 <-> 1 x OTU4
  • 2 x FC3200 <-> 2 x ODUflex <-> 1 x ODU4 <-> 1 x OTU4
  • 2 x FC1600 <-> 2 x ODUflex <-> 1 x ODU4 <-> 1 x OTU4
Client-side service type

100GE: Ethernet service at a rate of 103.125 Gbit/s.

OTU4: OTN service at a rate of 111.81 Gbit/s

FC1600: SAN service at a rate of 14.025 Gbit/s

FC3200: SAN service at a rate of 28.05 Gbit/s

OTN function
  • Supports OTUC2 or OTU4 interfaces on the WDM side.
  • Uses the frame formats and overhead processing methods defined in ITU-T G.709.
  • At the ODU4 layer:
    • Supports PM overhead processing when 100GE services are received on the client side.
    • Supports PM and TCM overhead processing when OTU4 services are received on the client side. This board supports non-intrusive monitoring of PM and TCM overheads.
  • Supports PM overhead processing at the ODUflex layer.
  • Supports PM overhead processing at the ODUC2 layer.
  • Supports SM overhead processing at the OTU4 layer on the client side.
  • Supports SM overhead processing at the OTUC2 and OTU4 layer on the WDM side.
WDM specification

Supports ITU-T G.694.1-compliant DWDM specifications.

Tunable wavelength functionLDC supports tunable wavelength optical modules that provide for 96 wavelengths tunable in the extended C band with 50 GHz channel spacing.
ESC function

Supported

PRBS test functionSupports the PRBS function on both the client side and WDM side.
NOTE:
When only OTU4 services are received, the PRBS function is supported on the client side.
LPT functionNot supported
FEC coding

On the client side:

Supports Supports ITU-T G.709-compliant forward error correction (FEC) on the client side when the client-side service type is OTU4.

Supports RS_FEC coding when the client-side service type is 100GE or FC3200.

On the WDM side:

Supports SDFEC-R coding.

NOTE:
Boards that use different FEC modes cannot interconnect with each other.
Alarm and performance event monitoring
  • Monitors BIP8 bytes (Bursty mode) to help locate line failures.
  • Monitors OTN alarms and performance events.
  • Monitors parameters such as the bias current, temperature, and optical power of the laser.
  • Supports the remote monitoring (RMON) of Ethernet services.

  • Supports the monitoring of CD and PMD performance.
Regeneration board

The WDM-side signals from an LDC board can be regenerated only by another LDC board of the same type.

ALS function

Supports the ALS function on the client side when client services are non-OTN services.

Test frameSupported only when the client-side service type is 100GE.
Latency measurementSupports bidirectional latency measurement at the ODUC2 (WDM side), ODU4 (WDM side / client-side) or ODUflex (client-side) layer between two OTU boards and displays latency data on the NMS.

When OTU4 services are received on the client side, latency measurement is not supported.

IEEE 1588v2Not supported
Physical clockThe board supports synchronous Ethernet transparent transmission instead of synchronous Ethernet processing
Ethernet service mapping mode

Bit Transparent Mapping ODU4, MAC Transparent Mapping ODU4

Electrical-layer ASONNot supported
Optical-layer ASONSupported
Ethernet service mapping modeBit Transparent Mapping ODU4, MAC Transparent Mapping ODU4, MAC Transparent Mapping ODUFlex
Protection scheme
  • Supports client 1+1 protection.
  • Supports intra-board 1+1 protection (when working with the OLP/DCP/QCP board).
  • When a (100GBASE-4×25G)-SR4-100m-QSFP28 module or an 112.2Gbit/s Multirate-0.1km-QSFP28 module is used on the client side, the LDC board does not support client 1+1 protection.
  • When 100GE services are received on the client side, client 1+1 protection supports bidirectional switching rather than unidirectional switching. When OTU4 services are received on the client side, client 1+1 protection supports unidirectional switching.
LoopbackODUk channel100G line: ODUflex channel loopbackSupported
200G line: ODU4 and ODUflex channel loopbacks
Client sideInloopSupported
Outloop
WDM sideInloopSupported
Outloop

Protocols or standards compliance

Protocols or standards for transparent transmission (non-performance monitoring)

IEEE 802.3ba

NCITS FIBRE CHANNEL PHYSICAL INTERFACES (FC-PI)

NCITS FIBRE CHANNEL LINK SERVICES (FC-LS)

NCITS FIBRE CHANNEL FRAMING AND SIGNALING-2 (FC-FS-2)

NCITS FIBRE CHANNEL BACKBONE-3 (FC-BB-3)

NCITS FIBRE CHANNEL SWITCH FABRIC-3 (FC-SW-3)

NCITS FIBRE CHANNEL - PHYSICAL AND SIGNALING INTERFACE (FC-PH)

Protocols or standards for service processing (performance monitoring)

ITU-T G.805

ITU-T G.806

ITU-T G.709

ITU-T G.872

ITU-T G.7710

ITU-T G.798

ITU-T G.874

ITU-T M.3100

ITU-T G.874.1

ITU-T G.875

ITU-T G.808.1

ITU-T G.841

ITU-T G.8201

ITU-T G.694.1

ITU-T G.8261

ITU-T G.8262

Table 2 Functions and features of the LDC board (in regeneration mode)
Function and FeatureDescription
Basic functionThe LDC board applies to electrical regeneration sites to provide the electrical regeneration function for optical signals.
Regeneration rate

OTUC2: a rate of 224.6 Gbit/s

OTU4: a rate of 111.81 Gbit/s

OTN function

200G regeneration:

  • Supports OTUC2 interfaces on the WDM side.
  • Uses the frame formats and overhead processing methods defined in ITU-T G.709.
  • ODUC2 layer: supports PM overhead processing, and non-intrusive monitoring of PM overheads.
  • OTUC2 layer: supports SM overhead processing.

100G regeneration:

  • Supports OTU4 interfaces on the WDM side.
  • Uses the frame formats and overhead processing methods defined in ITU-T G.709.
  • ODU4 layer: supports PM and TCM overhead processing, and non-intrusive monitoring of PM and TCM overheads.
  • OTU4 layer: supports SM overhead processing.
WDM specification

Supports ITU-T G.694.1-compliant DWDM specifications.

Tunable wavelength functionLDC supports tunable wavelength optical modules that provide for 96 wavelengths tunable in the extended C band with 50 GHz channel spacing.
ESC function

Supported

PRBS test functionNot supported
LPT functionNot supported
FEC coding
  • Supports SDFEC-R coding.

NOTE:
Boards that use different FEC modes cannot interconnect with each other.
Alarm and performance event monitoring
  • Monitors OTN alarms and performance events.
  • Monitors parameters such as the bias current, temperature, and optical power of the laser.
  • Supports CD and PMD performance monitoring.
ALS functionNot supported
Test frameNot supported
Electrical-layer ASONNot supported
Optical-layer ASONSupported
Protection schemeNot supported
LoopbackNot supported

Protocols or standards compliance

Protocols or standards for transparent transmission (non-performance monitoring)

-

Protocols or standards for service processing (performance monitoring)

ITU-T G.805

ITU-T G.806

ITU-T G.709

ITU-T G.872

ITU-T G.7710

ITU-T G.798

ITU-T G.874

ITU-T M.3100

ITU-T G.874.1

ITU-T G.875

ITU-T G.808.1

ITU-T G.841

ITU-T G.8201

ITU-T G.694.1

ITU-T G.8261

ITU-T G.8262

Mechanical Specifications

  • Dimensions of front panel (H x W x D): 264.6 mm (10.4 in.) x 25.4 mm (1.0 in.) x 220 mm (8.7 in.)
  • Weight: 1.8 kg (3.97 lb.)

Power Consumption

BoardTypical Power Consumption (W)Maximum Power Consumptiona (W)
TN11LDC90100
a: The maximum power consumption is the power consumed by the board when it works normally under the highest ambient temperature.
Delivery

Delivery OptionsEstimated Delivery Time
OptiX OSN 9800 TN11LDC 2 x 100Gbit/s Service Multiplexing Into OTUC2 Wavelength Conversion Board-- OSN9800 UPS OptiX OSN 9800 TN11LDC 2 x 100Gbit/s Service Multiplexing Into OTUC2 Wavelength Conversion Board-- OSN9800 UPSOptiX OSN 9800 TN11LDC 2 x 100Gbit/s Service Multiplexing Into OTUC2 Wavelength Conversion Board-- OSN9800 UPSDHL3-5 business days
OptiX OSN 9800 TN11LDC 2 x 100Gbit/s Service Multiplexing Into OTUC2 Wavelength Conversion Board-- OSN9800 UPS Fedex3-5 business days
OptiX OSN 9800 TN11LDC 2 x 100Gbit/s Service Multiplexing Into OTUC2 Wavelength Conversion Board-- OSN9800 UPS By Sea10-20 business days

OptiX OSN 9800 TN11LDC 2 x 100Gbit/s Service Multiplexing Into OTUC2 Wavelength Conversion Board-- OSN9800 UPSNotice:

Above mentioned information are just for your reference only,we will keep you posted for the tracking delivery schedule.There are two delivery options available for by air and by sea:

OptiX OSN 9800 TN11LDC 2 x 100Gbit/s Service Multiplexing Into OTUC2 Wavelength Conversion Board-- OSN9800 UPSDeliver to port:

Uonel is responsible for transporting goods to port. All subsequent customs and transportation fees are the
responsibility of the buyer. Uonel will recommend trustworthy local freight forwarders to you.Uonel can facilitate the progress under buyer's permission and at buyer's expense.

OptiX OSN 9800 TN11LDC 2 x 100Gbit/s Service Multiplexing Into OTUC2 Wavelength Conversion Board-- OSN9800 UPSDeliver to door:

Uonel will quote all destination charge prior once we have confirmed order.
Uonel is responsible for transporting goods to door after you have made the payment.

Warranty

OptiX OSN 9800 TN11LDC 2 x 100Gbit/s Service Multiplexing Into OTUC2 Wavelength Conversion Board-- OSN9800 UPS 100% Low Price Guarantee:
Uonel provides high-quality products at low wholesale prices


OptiX OSN 9800 TN11LDC 2 x 100Gbit/s Service Multiplexing Into OTUC2 Wavelength Conversion Board-- OSN9800 UPS 100% Quality Assurance:
All items are ORIGINAL NEW and GENUINE only.


OptiX OSN 9800 TN11LDC 2 x 100Gbit/s Service Multiplexing Into OTUC2 Wavelength Conversion Board-- OSN9800 UPS Free Technical Support:

Our FREE Huawei Expert Consultancy Support is over the phone, by chat, by email or by login remotely.


OptiX OSN 9800 TN11LDC 2 x 100Gbit/s Service Multiplexing Into OTUC2 Wavelength Conversion Board-- OSN9800 UPS 100% Money Back Guarantee:
You can contact our customer service team to exchange or return any product that you bought from us.


OptiX OSN 9800 TN11LDC 2 x 100Gbit/s Service Multiplexing Into OTUC2 Wavelength Conversion Board-- OSN9800 UPS Flexible Secure Payment & Shipment:
Verified authorization: Mcafee Secure, VeriSign Secured

Return Material Authorization (RMA) Process

Standard Hardware Warranty Policy:

Original new sealed Huawei product: 1 Year

The Support Contacts:

If your Huawei products failed, you must contact your sales representative to verify product failure. If the problem still can't correct by remote support methods i.e. email or phone support, the RMA procedure will issue.

Company Profile

Uonel is one of the biggest Huawei Network Hardware distributor in china, founded in 2008. We are a global provider of netwotking products with more than 5000 customers.

We provide original new Huawei Routers,Switches,Firewalls,Wireless APs & controllers,OLTs,GPON modems,optical transceivers.Our company have more than $5million Huawei products in stock.

Most of our technical engineers had work exprience in Huawei company,we can provide network design&planning,configration,troubleshooting,maintenance and training service in world wide.














China OptiX OSN 9800 TN11LDC 2 x 100Gbit/s Service Multiplexing Into OTUC2 Wavelength Conversion Board-- OSN9800 UPS wholesale

OptiX OSN 9800 TN11LDC 2 x 100Gbit/s Service Multiplexing Into OTUC2 Wavelength Conversion Board-- OSN9800 UPS Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Uonel Co.Limtied
*Subject:
*Message:
Characters Remaining: (0/3000)